API
api-cb logo
API-Camille Bauer Division of
Absolute Process Instruments, Inc.

Signal Conditioners, Signal Isolators, Process Transmitters
Electrical Power Monitors, Electrical Power Transducers,
Rotary Position Sensors
apicb API CecompGauges APCS products Rheintacho products
Power Transducers Multi-Function Meters Multi-Function Transducers LONWORKS MODBUS PROFIBUS Power & CurrentTransducers
Multi-Function Power Meters
Sineax A210 & A220 Multifunction Power Meters
Input: Single or 3-Phase
0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Digital Pulse
Relay
A210 and A220

CE logoemmodEMMOD
  • A210 1/4 DIN size or A220 Full-Size DIN
  • 19 Types of Measurements Including
  • P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
  • 3 Variable Display
  • Open Collector Alarm Relay and Pulse Outputs
  • Data Logging, RS232, and MODBUS with EMMOD 201 Option
  • Two Analog Outputs with EMMOD 202 Option
  • Ethernet Interface with EMMOD 203 Option
  • PROFIBUS Interface with EMMOD 204 Option
  • Hi/Lo Electrical Rates
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications
Instructions
EMMOD201>> A200Plus Software
EMMOD201 MODBUS
EMMOD202 Analog Outputs
EMMOD203
EMMOD203 Ethernet
EMMOD204
EMMOD204 PROFIBUS GSD File
Sineax A230 & A230s Multifunction Power Meter w. System Load & Harmonics
Input: Single or 3-Phase
0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Digital Pulse
Relay
A230 and A230s

CE logoemmod EMMOD


Top of page
  • A230 Full-Size DIN or A230s 1/4 DIN
  • 19 Types of Measurements Including
  • P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
  • Three 4-digit Programmable Displays
  • Open Collector Alarm Relay and Pulse Outputs
  • Data Logging, RS-232, and MODBUS with Optional EMMOD 201
  • Two Analog Outputs with EMMOD 202 Option
  • Ethernet Interface with EMMOD 203 Option
  • PROFIBUS Interface with EMMOD 204 Option
  • Hi/Lo Electrical Rates
  • Comprehensive mean and max./min. value functions with trend
  • System analysis functions (THD, harmonics, asymmetry)
  • Higher accuracy
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Brochure
Specifications
Instructions
EMMOD201>> A200Plus Software
EMMOD201 MODBUS
EMMOD202 Analog Output
EMMOD203
EMMOD203 Ethernet
EMMOD204
EMMOD204 PROFIBUS GSD File
Sineax A2000 True RMS Multifunction Power Meter
Input: Single or 3-Phase
0-1A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Programmable
4 Analog
2 Digital Pulse
2 Relays
a2000
a2000 back
Top of page
  • Display 4 Variables
  • Up to 4 Analog and 2 Pulse Outputs
  • Data Logging of any of 37 Values
  • 2 Relay Outputs
  • Alarm Contacts Triggered on any Setpoint
  • Includes Measurement & Configuration Software
  • MODBUS / LONBUS / PROFIBUS Versions
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Brochure
CE logo Specifications
Instructions
MetraWin Software
Multi-Function Energy Transducers
Sineax CAM Multifunction Energy Transducer
Input: 0-1A, 0-5 A or
Two 4-20 mA
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Digital I/O
Output: RS-485 MODBUS Interface
USB 2.0
Relay
Up to 4 analog
Digital I/O
CAM
Top of page
NEW Product!
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • USB Programming Interface
  • 85-265 VAC/ 110-265 VDC Powered
  • Optional 17-90 VDC powered
CE logo Specifications
Instructions
CAM Software
MODBUS Instructions
Sineax A200 Multifunction Display for DME Power Transducers
Input: Serial Data from DME4 Series Output: 3 Digital Displays A200 Top of page
  • 1/4 DIN (96 x 96 mm) Display for DME4 transducers
  • Triple LED Display 14 mm Digit Height
  • Selectable Display Parameters
  • 20-265 VAC/VDC Powered
CE logo
Specifications
Instructions
Sineax DME 400 Energy Transducer with LONWORKS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: LONWORKS with LONTalk Protocol DME 400
Top of page
lonworks logo
  • LONWORKS Interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
DME Software
LONWORKS Instructions
Sineax DME 401 Energy Transducer with MODBUS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: RS-485 MODBUS Interface DME 401
Top of page
  • RS-485 MODBUS Interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
DME Software
MODBUS Instructions
MODBUS Basics
Sineax DME 440 Energy Transducer w. MODBUS & 4 Analog Outputs
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: RS-485 MODBUS Interface
4 analog outputs:
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
DME 440
Top of page
  • RS-485 MODBUS Interface
  • 4 analog outputs
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
DME Software
Sineax DME 406 Energy Transducer with PROFIBUS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: PROFIBUS DP DME 406

Top of page
profibus logo
  • PROFIBUS DP Interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
DME Software
PROFIBUS Instructions
PROFIBUS GSD File
Sineax DME 424 & DME 442 Energy Transducers w. Analog and Pulse Outputs
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: 0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open Collector Pulse
DME 442

Top of page
  • DME 424 with 2 analog and 4 digital pulse outputs
  • DME 442 with 4 analog and 2 digital pulse outputs
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin j, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
DME Software
Power & Current Transducers
Sineax M 561 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: One Analog Output
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M 561
Top of page
  • 1 Analog Output
  • Measures any One: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCAS logo Specifications
Instructions
Software
Sineax M 562 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: 2 Analog Outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M562
Top of page
  • 2 Analog Outputs
  • Measures any Two: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logo CSA logo Specifications
Instructions
Software
Sineax M 563 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: 3 Analog Outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M 563
Top of page
  • 3 Analog Outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
CE logoCSA logo Specifications
Instructions
Software

Phone:  800-942-0315 or 847-918-3510   Fax:  800-949-7502 or 847-968-4891
apicb.com Home Page
Copyright © 1999-2010 Absolute Process Instruments, Inc.