API
api-cb logo
API-Camille Bauer Division of
Absolute Process Instruments, Inc.

Signal Conditioners, Signal Isolators, Process Transmitters
Electrical Power Monitors, Electrical Power Transducers,
Rotary Position Sensors
apicb API CecompGauges APCS products Rheintacho products
Isolators
Sineax TI 816 Signal Isolator 500 V
Input: 0-20 mA, 4-20 mA

Output: 0-20 mA, 4-20 mA, 0-10 V to 2-10 V
  • Loop-Powered Passive Device
  • Order with V or mA Output
  • 600 Ω Maximum Burden (Current)
  • 500 Ω Maximum Burden (Voltage)
  • Only 0.5" (12.5 mm) Wide
  • Low Cost
CE logo Data Sheet
Instructions
CE Declaration
TI 816
Sineax DCM 817 Signal Isolator 500 V
Input: 0-20 mA, 4-20 mA

Output: 0-20 mA, 4-20 mA
  • Circuit Board Mounted
  • Straight Pins or 90° Pins
  • Loop-Powered Passive Device
  • 600 Ω Maximum Burden
  • Compact and Cost Effective OEM Solution
CE logo Data Sheet
DCM 817st DCM817
Top of page
Sineax SI 815-5 and SI 815-5 Signal Isolators Up to 2300 V Isolation
Input: One or Two 4-20 mA

Output: One or Two 4-20 mA hart logo
  • Single Channel (SI 815-5) and Two Channel (SI 815-1) Versions
  • Output Loop Powered (12-30 V)
  • Transfers Power to Input Loop
  • Optional HART Protocol
CE logo Data Sheet Both Versions
Instructions Single Channel Versions
Instructions Two Channel Versions
CE Declaration Both Versions
sineax si815 SI 815-1 two channel
Top of page
Sineax TI 807-5, TI 807-1 Signal Isolators up to 4000 V Isolation
Input: One, Two, or Three 0-20 mA, 4-20 mA, 0-10 V

Output: One, Two, or Three 0-20 mA, 4-20 mA, 0-10 V
  • Single Channel (TI 807-5) and Two/Three Channel (TI 807-1) Versions
  • Loop-Powered Passive Device
  • 1000 Ω Maximum Burden
  • Factory Ranged
CE logo Data Sheet All Versions
Instructions Single Channel Versions
Instructions Two or Three Channel Versions
CE Declaration All Versions
sineax ti807 ti807-5
Top of page
Splitters & Amplifiers
Sineax TV 808 One-Channel Isolator / Amplifier
Input: 4-20 mA, 0-40 mA, ±40 mA, 0-40 V, ±40 V

Output: 0-20 mA, 4-20 mA, ±20 mA, 0-10 V, ±10 V
  • 3.7 kV I/O to Power Supply Isolation
  • 2.3 kV Input to Output Isolation
  • Jumper Configurable Input and Output Settings
  • Zero and Span Adjustments
  • Power: 24-60 VAC/VDC or 85-230 VAC/VDC
CE logo Data Sheet, One Channel Versions Instructions, One Channel Versions
Data Sheet, One Channel Versions w. HART option
Instructions, One Channel Versions w. HART option
CE Declaration, all TV808
TV 808
Top of page
Sineax TV 808-12 Two-Channel Isolator / Amplifier
Input: 4-20 mA, 0-40 mA, ±40 mA, 0-40 V, ±40 V

Output: 0-20 mA, 4-20 mA, ±20 mA, 0-10 V, ±10 V
  • Dual Channel Versions
  • Signal Splitter Versions
  • 3.7 kV I/O to Power Supply Isolation
  • 2.3 kV Input to Output Isolation
  • Zero and Span Adjustment for Each Channel
  • Factory Configured Input and Output Settings
CE logo Data Sheet, Two Channel Versions
Instructions, Two Channel Versions
CE Declaration, all TV808
TV 808
Top of page
Process & Universal Transmitters
Sineax TV 819 Low Cost Process Transmitter
Input: 0-60 mV to 0-1000V, 0-20 mA to ±40 mA

Output: 0-20 mA to ±20 mA, 0-10 V to ±10 V
  • Fully Isolated
  • Removable Plugs
  • Unipolar or Bipolar Input and Output
  • Factory Configured
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
sineax tv819
Top of page
Sineax TV 809 Programmable Process Transmitter
Input: 0-30 mV to 0-1000V, 0-20 µA to 0-100 mA

Output: 0-20 mA to ±20 mA, 20-4 mA, 0-10 V to ±10 V, 10-0 V
  • Fully Isolated
  • Removable Plugs
  • Unipolar or Bipolar Input and Output
  • Reverse Output Available
  • Custom 57 Point Input Linearization
  • Optional Programmable Relay Alarm
  • PC Programmable
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
TV800Plus Software
TV 809
Top of page
Sineax V 604s Programmable Universal Transmitter
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Modbus new product
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo Brochure
Data Sheet
Instructions
Safety Instructions
CE Declaration
CB Manager Software
V604s

Top of page
Sineax VB 604s Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
new product
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
Data Sheet
Instructions
Safety Instructions
CE Declaration
CB Manager Software
V604s

Top of page
Sineax V 604 Programmable Universal Transmitter
Input: 0-2 mV to ±40 V, 0-80 µA to -50-100 mA, Thermocouple, RTD, Thermistor, Potentiometer

Output: 0-5 mA to ±40 mA, 0-4 V to -12 to +15 V
  • PC Programmable
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Alarm Relay
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
V 604
Top of page
Sineax VC 603 Programmable Universal Transmitter with Alarms
Input: 0-2 mV to ±40 V, 0-80 µA to -50-100 mA, Thermocouple, RTD, Thermistor, Potentiometer

Output: 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: 1 DPDT, 2 SPDT
  • PC Programmable
  • 3 Independently Configurable Alarm Contacts
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
VC600 Software
VC 603
Top of page
Loop Power Supplies
Sineax B 840 Multi-Channel Loop Power Supply
Input: 24, 115, or 230 VAC

Output: 4-20 mA, 24 VDC
  • 4-Channel 4-20 mA, 24 V DC Versions
  • LED Monitor for Each Channel
  • Each Channel Isolated
  • Supply Voltage: 24, 115, or 230 VAC 50/60 Hz
  • 30 mA Current Limiter for Each Channel
CE logo Data Sheet
Instructions
CE Declaration
sineax b840
Top of page
Sineax B 812 Loop Power Supply with HART Communications
Input: 4-20 mA, 18 to 25.5 VDC, Source resistance 330 Ω

Output: 4-20 mA, 17 VDC no load, Permitted load: 750 Ω, 550 Ω with HART
Hart logo
  • 3.6 kV Input, Output, and Power Isolation
  • Red LED for Open and Short Circuit Fault Detection
  • Supply Voltage: 20-70 or 60-265 VAC/VDC (45-400 Hz for AC)
  • Designed for HART Protocol
CE logo Data Sheet
Instructions
CE Declaration
B 812
Top of page

Phone:  800-942-0315 or 847-918-3510   Fax:  800-949-7502 or 847-968-4891
apicb.com Home Page
Copyright © 1999-2012 Absolute Process Instruments, Inc.